ASTRO (Optional Feature)
Voice Testing: ASTRO -compatible vocoder for
both generator and receiver provides
functional voice testing capability via
internal speaker and microphone
accessory. Scope display of voice
waveform can also be selected.
EMBEDDED Link Control Field (LCF)
SIGNALING Presentation Address (PA)
Encode Capability: Key ID
Network ID
Busy Bits
Encode
Operator Entry: A default configuration can be selected
or a detailed special screen can be
accessed for customized programming.
Decoding Operation: A dedicated screen may be selected to
display and decode the same data as
described in the encode section. The
unit can also buffer 30 frames of data
on a first-in/first-out basis with the
capability to selectively recall any of
the stored frames to the screen.
BER Capability: Free running, unframed V.52 pseudo
random non-encrypted sequence
compatible with ASTRO test mode.
Measurement range from
0 to 20% bit errors.
Encryption Capability: DVP-XL, DES-XL, DVI-XL. For each
of these algorithms, the unit can accept
customer keys from Motorola external key
loaders (DX Compatible).
ASTRO single key software encryption is
also supported. A single side connector
is provided for key loading.
Generate Capability: ASTRO Voice Frames containing both
VSELP vocoded voice and embedded
signaling or an unframed V.52 pseudo
random non-encrypted sequence.
Monitor Capability: ASTRO Voice Frames containing both
VSELP vocoded voice and embedded
signaling or an unframed V.52 pseudo
random non-encrypted sequence.
Duplex Capability: An unframed V.52 pseudo random
non-encrypted sequence.
Project 25 Conventional (Optional Feature)
Voice Testing: Project 25-compatible IMBE vocoder
for both generator and receiver
provides functional voice testing
capability via internal speaker and
microphone accessory. Scope display
of voice waveform can also be selected.
EMBEDDED
SIGNALING
Encode Capability: Link Control Field (LCF)
Low Speed Data (LSD)
Key ID
Network ID
Status Symbol
Encode Operator Entry: A default configuration can be selected
or a detailed special screen can be
accessed for customized programming.
Decoding Operation: A dedicated screen may be selected to
display and decode the same data as
described in the encode section. The
unit can also buffer 30 frames of data
on a first-in/first-out basis with the
capability to selectively recall any of
the stored frames to the screen.
BER Capability: Compute BER from received non-
encrypted 1011 Hz tone test pattern.
Generate non-encrypted 1011 Hz tone
test pattern or a calibration test pattern
(generates 4.977% BER)for UUT BER
calculation with Project 25 test mode.
Encryption Capability: AES,
DES-OFB, DVP-XL, DES-XL, DVI-XL.
For each of these algorithms, the unit
can accept customer keys from Motorola
external key loaders (DX compatible).
A single side connector is provided for
key loading.
Generate Capability: Project 25 Standard Voice Frames
containing both IMBE vocoded voice
and embedded signaling, a standard
1011 Hz tone test pattern, a calibration
test pattern and a standard silence
test pattern.
Monitor Capability: Either Project 25 Standard Voice
Frames containing IMBE vocoded
voice and embedded signaling or
a standard 1011 Hz tone test pattern.
Project 25 Trunking (Optional Feature)
Call Sequence Tests: Registration/Call Alert
Dispatch Voice
Project 25 Trunking
Test Parameter Entries: WACN ID, System ID, WUID (or UID),
WGID (or GID), RFSS ID, Site ID, IDEN_UP
Test measurement display: Call sequence status indicator
WACN ID, System ID, UID, GID,
WUID, WGID
Frequency Bands: 800MHz – 851.00625MHz – 876.59375MHz)
with a -45Mhz offset. Channel plan #1.
700MHz – 762.00625MHz – 787.59375MHz)
with a +30MHz offset. Channel plan #2.
UHF/VHF – User-defined channel plan.
The channel plan range is 1 thru 16. This
can also be used to define non-standard
700MHz channel plans.
Generate
Deviation Selection: 0.00kHz – 5.00kHz
Base Station Tests: Full duplex modulation of 1011 Hz test
pattern with simultaneous C4FM/LSM
demodulation of voice. Also includes an
averaging wattmeter with selectable
period (.09 sec to 4.32 sec) and an
accuracy of ±15%. Input range is from
.5 watts to 125 watts peak.
BER Capability: Free running, unframed V.52 pseudo
random non-encrypted sequence.
Measurement range from 0 to 20%
bit errors.
Trunking (Cont.)
Trunking Test
Parameter Entries: (Dependent on Test Selection)
Signaling Type
Call Sequence
System ID
Size Code
Connect Tone
Frequency Band
Control and Traffic Channel (by
frequency and channel number)
Test Measurement
Display: Call Sequence Status Indicator
Radio ID (Hex or Decimal)
Call Type
RF Performance Data (via exit to
standard screens)
Radio ID Decoding: Type I: Fleet, Sub-fleet & Unit ID
Type II: Talk Group, Unit ID
Smart Zone
Test Support: Auto affiliation test
Frequency Bands: 851-870 MHz, 866-870 MHz Split
Channel
935-941 MHz, 850-860 MHz JSMR
403-522 MHz UHF, 132-175 MHz VHF
Generate Deviation
Selection: 1.2 kHz, 2.4 kHz, 3.125 kHz
Type I System
Configuration Storage: Non-volatile storage of up to 10 fleet
maps with alpha numeric entries
Channel Plan
Entry for VHF/UHF: Separate transmitter and receiver
start-and-end frequency for three blocks.
Independent channel spacing for
each block.