10
Feature Description Benefits
Project 25, ASTRO and SECURENET Common Features
Encryption Test Option
Voice and embedded data encode and decode
testing can also be done in the encrypted
mode using either test keys, which are
permanently stored in the R2670, or actual
customer-selected keys which can be loaded
into the unit using a compatible key loader.
This feature allows verification of the proper
operation and system compatibility using
actual encryption algorithms.
Baseband Audio Scope Display
This display provides a clear graphic image of
the audio baseband, signal-selectable at either
the vocoder input in generate mode or the
vocoder output in monitor mode.
This feature provides greater assurance of
proper system operation through its graphic
display of voice or tone modulation.
ASTRO Test Option
Feature Description Benefits
Dedicated Test Screens
Conveniently accessed, dedicated test screens
can be set up as a start-up default condition
or as a programmable test set-up. Dedicated
ASTRO test screens are windowed with RF and
Modulation control screens to simultaneously
display test results along with their test
conditions. While in ASTRO mode, standard
diagnostic test screens can be easily
accessed.
This feature makes testing easier and
more efficient. It also provides quantitative RF
measurements to ensure proper system
performance margin.
Voice Mode System Testing
This feature provides ASTRO compatible FDMA
Digital C4FM modulation and demodulation
with vocoding and embedded data testing.
Generate and monitor modes support actual
functional voice testing. Within the voice
mode, embedded data can be encoded and
decoded for either subscriber or fixed site
radio equipment.
This feature allows you to verify operation and
system compatibility under actual operating
conditions for increased confidence of proper
system performance.
Bit Error Rate (BER) Testing
BER testing can be performed on radios
that support BER test capability. The R2670 in
ASTRO mode can generate or monitor
RF transmissions modulated with a V.52 BER
test pattern.
This testing provides an accurate quantitative
measurement of modulation quality and overall
system performance. The Duplex mode
supports loop-back testing.
(Optional in R2670; not available in R2600 and R2625)